Difference between revisions of "20.109(F08): Mod 2 Day 5 Probe western, isolate RNA"

From Course Wiki
Jump to: navigation, search
Line 22: Line 22:
 
==Protocols==
 
==Protocols==
  
Though the details of how to do this are not explicitly described, '''the spot tests from last time should be assessed.''' Be sure to ask questions of the teaching faculty if you're not sure how to interpret what you see.  
+
Though the details of how to do this are not explicitly described, '''the spot tests from last time should be assessed.''' Be sure to ask questions of the teaching faculty if you're not sure how to interpret what you see. You should photograph or scan your plates to include when you write up this work as a research article.
 
   
 
   
 
===Part 1: Probe Western blot===
 
===Part 1: Probe Western blot===
Line 38: Line 38:
  
 
===Part 2: RNA isolation===
 
===Part 2: RNA isolation===
 +
RNA is strikingly different from DNA in its stability. Consequently it is more difficult to work with RNA in the lab. It is not the techniques themselves that are difficult; indeed, many of the manipulations will seem identical to those used for DNA. However, RNA is rapidly and easily degraded by RNases that exist everywhere. There are several rules for working with RNA. They will improve your chances of success.  Please follow them all.
 +
*Use warm water on a paper towel to wash lab equipment, like microfuges, before you begin your experiment. Then wipe them down with “RNase-away” solution.
 +
*Wear gloves when you are touching anything that will touch your RNA.
 +
*Change your gloves often.
 +
*Before you begin your experiment clean your work area, removing all clutter. Wipe down the benchtop with warm water then “RNase-away,” and then lay down a fresh piece of benchpaper.
 +
*Use RNA-dedicated solutions and if possible RNA-dedicated pipetmen. 
 +
*Start a new box of pipet tips and label their lid “RNA ONLY.”
 +
To isolate the RNA from our yeast cells, we will use a kit manufactured by a company named Ambion. The contents of many solutions in their "RiboPure" Yeast RNA isolation kit are proprietary while some of the solutions they disclose are very hazardous. The protocol here will make very clear when you're working with anything dangerous and how to proceed. '''Please be sure to follow all these instructions carefully.'''
  
 +
#Decide which '''two''' strains you'd like to compare. One strain should be the parental strain, NY411. The other strain should be one of your TAP-tagged candidates.
 +
#Using the OD600 values that you measured last time, calculate the volume of each yeast strain you'll need in order to collect 1x10^8 cells using the fact that a reading of 5 OD600 can be roughly assumed to have 1x10^8 cells/ml. You can check your calculation with one of the teaching faculty if you want to.
 +
#Retrieve the needed yeast cultures from last time, vortex them to resuspend the cells, and move the calculated volume of each strain into properly labeled eppendorf tubes.
 +
#Aspirate the supernatant off the cells, using an RNAse-free pipet tip to cover the aspirator pipet and change tips each time.
 +
#Resuspend each pellet in 480 ul "Lysis Buffer." Pipet the pellet up and down to resuspend it.
 +
#Add 48 ul 10% SDS and with a gloved finger, flick the tubes to mix.[[Image:ZirconiaBeads.png|100 px|thumb|right| Measuring Zirconia beads]]
 +
#Put on a lab coat, eye protection, and a double layer of gloves. Move your rack of tubes to the chemical hood. Add 480 ul of Phenol:Chloroform:Isoamylalcohol to each sample. '''NOTE: THIS REAGENT IS VERY TOXIC. ''' Pipet tips should be directly ejected into the PCI waste container stored in the hood. If you believe you have spilled or splashed this reagent, please let one of the faculty know.
 +
#Using the vortex in the hood, vortex each cell lysis mixture for 15 seconds. Leave your tubes in a rack in the hood until you have completed the next step.
 +
#Retrieve the cold Zirconia beads and two screw capped tube from the teaching faculty. Pour the beads into the tube to a height of ~2.5 cm (~1 inch) from the bottom of the tube. See the picture here as a guide. Take the tubes and their caps to the hood.
 +
# Back at the chemical hood, transfer the mixture of cells and lysis reagents to the tube of beads. Secure the lid VERY tightly.
 +
#Position the samples hoerizontally on the vortex adapter with the tube caps towared the center. Beat the cells open by vortexing 10 minutes.
 +
#Transfer the tubes to an eppendorf centrifuge for 5 minutes at 13.2 rpm (full microfuge)
 
DONE!
 
DONE!
  

Revision as of 02:19, 17 August 2008


20.109(F08): Laboratory Fundamentals of Biological Engineering

20.109(F08)pic.jpg

Home        People        Schedule Fall 2008        Assignments        Lab Basics        OWW Basics       
DNA Engineering        Protein Engineering        Biomaterials Engineering              

Introduction

Antibodies are useful tools in the lab. Today we'll use antibodies to detect a protein on a blot. This technique, called Western analysis, can give us information about the size and concentration of the protein in the pool that was separated by SDS-PAGE. In our case, we'll use a Western to charaterize the TAP-tagged proteins we've generated. You could imagine a case where the genome has the correct TAP-TRP sequence but the resulting protein is unstable or expressed at such a low level that it's not seen on a Western. Alternatively, there are proteases in cells that might cleave the TAP-tag off the protein we've attached it to. Both of these outcomes are possible (even common!), and are important pieces of data to gather before performing a TAP purification of the tagged complex. Assuming the protein we're interested in is expressed and intact, then in general, the quality of Western results depends on the quality of the antibody we choose.

Luckily for Western analysis, a high quality antibody can have a relatively low affinity for its target protein. This is because the target is localized and concentrated on a blot, allowing the antibody to bind using both antibody “arms” thereby strengthening the association. Even an antibody that is loosely bound to the blot under these circumstances may dissociate then re-associate quickly since the local concentration of the target protein is high. The lower limit for protein detection is approximately 1 ng/lane, a value that varies with the size of the protein to be detected and the Western blotting apparatus that is used. For most acrylamide gels, the protein capacity for each lane is usually 200 to 400 ug (that would be 40 ul of a 5-10 ug/ul protein preparation). Thus 1 ng represents a protein that is approximately 0.0005-0.001% of the total cellular protein (1 ng out of 200,000-400,000 ng). Obviously proteins that make up a more significant fraction of the total protein population will be easier to detect.

Many species can be used to raise antibodies. Most commonly mice, rabbits, and goats are immunized, but other animals like sheep, chickens, rats and even humans can be used. The protein used to raise an antibody is called the antigen and the portion of the antigen that is recognized by an antibody is called the epitope. Each antibody can recognize only a small portion of its antigen, typically 5 to 6 amino acids. Some antibodies are monoclonal, or more appropriately “monospecific,” and recognize one epitope, while other antibodies, called polyclonal antibodies, are in fact antibody pools that recognize multiple epitopes. We will be using a polyclonal antibody raised in rabbits against the Protein A from Staphylococcus aureus, but for the sake of completion, the origin of both polyclonal and monoclonal antibodies are described.

generating polyclonal antibodies

To raise polyclonal antibodies, the antigen of interest is first purified and then injected into an animal. To elicit and enhance the animal’s immunogenic response, the antigen is often injected multiple times over several weeks in the presence of an immune-boosting compound called adjuvant. After some time, usually 4 to 8 weeks, samples of the animal’s blood are collected and the cellular fraction is removed by centrifugation. What is left, called the serum, can then be tested in the lab for the presence of specific antibodies. Even the very best antisera have no more than 10% of their antibodies directed against a particular antigen. The quality of any antiserum is judged by its purity (that it has few other antibodies), its specificity (that it recognizes the antigen and not other spurious proteins) and its concentration (sometimes called its titer). Animals with strong responses to an antigen can be boosted with the antigen and then bled many times, so large volumes of antisera can be produced. However animals have limited life-spans and even the largest volumes of antiserum will eventually run out, requiring a new animal for immunization. The purity, specificity and titer of the new antiserum will likely differ from that of the first batch. High titer antisera against bacterial and viral proteins can be particularly precious since these antibodies are difficult to raise; most animals have seen these immunogens before and therefore don’t mount a major immune response when immunized. Antibodies against toxic proteins are also challenging to produce if they make the animals sick.

generating monoclonal antibodies

Monoclonal antibodies overcome many limitations of polyclonal pools in that they are specific to a particular epitope and can be produced in unlimited quantities. However, more time is required to establish these antibody-producing cells, called hybridomas, and it is a more expensive endeavor. Antibody-secreting cells are first isolated from an immunized animal, usually a mouse, and then fused with an immortalized cell line such as a myeloma. The fusion can be accomplished by incubating the cells with polyethylene glycol (antifreeze), which facilitates the joining of the plasma membranes of the two cell types. A fused cell with two nuclei can be resolved into a stable hybridoma after mitosis. The unfused antibody-secreting cells have a limited lifespan and so die out of the hybridoma population, but the myelomas must be removed with some selection against the unfused cells. Production of stable hybridomas is tedious and difficult but often worth the effort since monoclonal antibodies can recognize covalently-modified epitopes specifically. These are invaluable for experimentally distinguishing the phosphorylated or glycosylated forms of an antigen from the unmodified forms.

The mechanics of probing your blot with antibodies is neither complicated nor interesting. The blot will be washed, incubated for an hour with the primary antibody that recognizes Protein A, washed again, then incubated for another hour with a second antibody raised in goats that recognizes rabbit antibodies. This secondary antibody will amplify the primary signal and also enable us to detect where on the blot the antibodies have bound (through an enzymatic reaction with the alkaline phosphatase substrates to precipitate a colored compound on the blot).

Since the actual manipulations of the Western are not time consuming, we'll also begin work on another portion of this experimental module, namely the microarray analysis of total gene expression. You'll isolate RNA as described below from the parental strain, NY411 and whichever of the two yeast candidates you have the most confidence in. Finally, you should also take some time to examine and photograph the spot plates you set up last time. Busy but exciting day!

Protocols

Though the details of how to do this are not explicitly described, the spot tests from last time should be assessed. Be sure to ask questions of the teaching faculty if you're not sure how to interpret what you see. You should photograph or scan your plates to include when you write up this work as a research article.

Part 1: Probe Western blot

  1. You should retrieve the blot that you made last time and pour the TBS-T + milk solution into a 50 ml conical tube.
  2. Measure 15 ml of the TBS-T + milk in a 15 ml falcon tube.
  3. Add 15 ul of anti-ProtA antibody to the falcon tube and invert several times to mix.
  4. Pour the antibody solution over the blot, cover the container, label it with your team color and place it on the platform shaker that's in the chemical hood for 45 minutes-1 hour. During this time, you should work on Part 2 of today's protocol, namely isolating RNA from your yeast cell
  5. Pour the primary antibody solution into a conical tube, writing the identity of the antibody and today's date on the tube.
  6. Give your blot a quick rinse with TBS-T, enough to cover the blot (volume is not critical here).
  7. Wash the blot on the platform shaker 2 times with TBS-T at room temperature, five minutes per wash. Again the volume of the wash solution is not critical.
  8. Add secondary antibody (1:1000 Goat-antimouse-alkaline phosphatase) in 15 ml TBS-T and incubate on the platform shaker at room temperature for 30-60 minutes. During this time, you should continue your work on Part 2 of today's protocol
  9. Wash the blot as before (rinse and two washes).
  10. When you are done washing, mix 250 ul of each of the solutions from the alkaline phosphatase substrate kit into the provided tube of 25 ml 1X developing solution.
  11. Add developing solution and shake on the platform shaker watching for color to develop. Rinse the blot with water when bands are evident (you should anticipate what size protein you are looking for) but before the background of the blot becomes discolored. One of the teaching faculty will scan the blot and post the results for you.

Part 2: RNA isolation

RNA is strikingly different from DNA in its stability. Consequently it is more difficult to work with RNA in the lab. It is not the techniques themselves that are difficult; indeed, many of the manipulations will seem identical to those used for DNA. However, RNA is rapidly and easily degraded by RNases that exist everywhere. There are several rules for working with RNA. They will improve your chances of success. Please follow them all.

  • Use warm water on a paper towel to wash lab equipment, like microfuges, before you begin your experiment. Then wipe them down with “RNase-away” solution.
  • Wear gloves when you are touching anything that will touch your RNA.
  • Change your gloves often.
  • Before you begin your experiment clean your work area, removing all clutter. Wipe down the benchtop with warm water then “RNase-away,” and then lay down a fresh piece of benchpaper.
  • Use RNA-dedicated solutions and if possible RNA-dedicated pipetmen.
  • Start a new box of pipet tips and label their lid “RNA ONLY.”

To isolate the RNA from our yeast cells, we will use a kit manufactured by a company named Ambion. The contents of many solutions in their "RiboPure" Yeast RNA isolation kit are proprietary while some of the solutions they disclose are very hazardous. The protocol here will make very clear when you're working with anything dangerous and how to proceed. Please be sure to follow all these instructions carefully.

  1. Decide which two strains you'd like to compare. One strain should be the parental strain, NY411. The other strain should be one of your TAP-tagged candidates.
  2. Using the OD600 values that you measured last time, calculate the volume of each yeast strain you'll need in order to collect 1x10^8 cells using the fact that a reading of 5 OD600 can be roughly assumed to have 1x10^8 cells/ml. You can check your calculation with one of the teaching faculty if you want to.
  3. Retrieve the needed yeast cultures from last time, vortex them to resuspend the cells, and move the calculated volume of each strain into properly labeled eppendorf tubes.
  4. Aspirate the supernatant off the cells, using an RNAse-free pipet tip to cover the aspirator pipet and change tips each time.
  5. Resuspend each pellet in 480 ul "Lysis Buffer." Pipet the pellet up and down to resuspend it.
  6. Add 48 ul 10% SDS and with a gloved finger, flick the tubes to mix.
    Measuring Zirconia beads
  7. Put on a lab coat, eye protection, and a double layer of gloves. Move your rack of tubes to the chemical hood. Add 480 ul of Phenol:Chloroform:Isoamylalcohol to each sample. NOTE: THIS REAGENT IS VERY TOXIC. Pipet tips should be directly ejected into the PCI waste container stored in the hood. If you believe you have spilled or splashed this reagent, please let one of the faculty know.
  8. Using the vortex in the hood, vortex each cell lysis mixture for 15 seconds. Leave your tubes in a rack in the hood until you have completed the next step.
  9. Retrieve the cold Zirconia beads and two screw capped tube from the teaching faculty. Pour the beads into the tube to a height of ~2.5 cm (~1 inch) from the bottom of the tube. See the picture here as a guide. Take the tubes and their caps to the hood.
  10. Back at the chemical hood, transfer the mixture of cells and lysis reagents to the tube of beads. Secure the lid VERY tightly.
  11. Position the samples hoerizontally on the vortex adapter with the tube caps towared the center. Beat the cells open by vortexing 10 minutes.
  12. Transfer the tubes to an eppendorf centrifuge for 5 minutes at 13.2 rpm (full microfuge)

DONE!

For next time

  1. Figure of spot tests.
  2. Figure of Western.

Reagents list

  • TBS-T Tris-Buffered Saline + Tween
  • polyclonal anti-protA, raised in mouse cells
  • polyclonal antimouse-AP from BioRad, raised in goat
  • BioRad AP detection reagents
    • 1 ml 25x detection stock + 24 ml H2O with 0.25 ml solnA and 0.25 ml solnB.