Difference between revisions of "20.109(F16):Induce CRISPRi system (Day7)"

From Course Wiki
Jump to: navigation, search
(Part 1: Communication Lab workshop)
(Part 2: Examine psgRNA sequencing results)
Line 33: Line 33:
 
If both colonies for your mutant have the correct sequence, choose one to use for the protein purification step. If only one is correct, then this is the one you will use next time. If neither of your plasmids carry the appropriate mutation, talk to the teaching faculty.  
 
If both colonies for your mutant have the correct sequence, choose one to use for the protein purification step. If only one is correct, then this is the one you will use next time. If neither of your plasmids carry the appropriate mutation, talk to the teaching faculty.  
  
<b>Align with "bl2seq" from [http://www.ncbi.nlm.nih.gov/ NCBI]</b>
+
'''Align with "bl2seq" from [http://www.ncbi.nlm.nih.gov/ NCBI]'''
 
#The "nucleotide BLAST" alignment program can be accessed through the NCBI [http://www.ncbi.nlm.nih.gov/BLAST/ BLAST page] or directly from this [http://www.ncbi.nlm.nih.gov/blast/bl2seq/wblast2.cgi link]. The default settings should be fine.
 
#The "nucleotide BLAST" alignment program can be accessed through the NCBI [http://www.ncbi.nlm.nih.gov/BLAST/ BLAST page] or directly from this [http://www.ncbi.nlm.nih.gov/blast/bl2seq/wblast2.cgi link]. The default settings should be fine.
 
#Paste the sequence text from your sequencing run into the "Query" box. This will now be the "query." If there were ambiguous areas of your sequencing results, these will be listed as "N" rather than "A" "T" "G" or "C" and it's fine to include Ns in the query.  
 
#Paste the sequence text from your sequencing run into the "Query" box. This will now be the "query." If there were ambiguous areas of your sequencing results, these will be listed as "N" rather than "A" "T" "G" or "C" and it's fine to include Ns in the query.  
 
#*The start and end of your sequencing may have several Ns.  In this case it is best to omit these Ns by pasting only the 'good' sequence that is flanked by the ambiguous sequence.
 
#*The start and end of your sequencing may have several Ns.  In this case it is best to omit these Ns by pasting only the 'good' sequence that is flanked by the ambiguous sequence.
 
#Paste the pRSET-IPC or CaM sequence into the "Subject" box.  
 
#Paste the pRSET-IPC or CaM sequence into the "Subject" box.  
#Click on the BLAST button. Matches will be shown by vertical lines between the aligned sequences. You should see a long stream of matches, followed by lots of errors in the last ~200 bp of the sequence ��� ignore the error-ridden part of the data, as it may not accurately reflect your mutant plasmid. In this stream of matches, the 1 missing line indicating your mutant codon should stand out. If it doesn't, use the numbering or Find tool to locate the appropriate codon.  
+
#Click on the BLAST button. Matches will be shown by vertical lines between the aligned sequences. You should see a long stream of matches, followed by lots of errors in the last ~200 bp of the sequence.
 +
#*Ignore the error-ridden part of the data, as it may not accurately reflect your mutant plasmid. In this stream of matches, the 1 missing line indicating your mutant codon should stand out. If it doesn't, use the numbering or Find tool to locate the appropriate codon.  
 
#Carefully examine the sequence to see if your mutation was incorporated.  
 
#Carefully examine the sequence to see if your mutation was incorporated.  
 
#You should save a screenshot of each alignment and attach them to your notebook.
 
#You should save a screenshot of each alignment and attach them to your notebook.
#Follow the above steps to examine all of your sequencing results.  '''Remember: you used a forward and a reverse primer to interrogate both potentially mutated plasmids.'''  
+
#Follow the above steps to examine all of your sequencing results.  '''Remember: you used a forward and a reverse primer to interrogate both potentially mutated plasmids.'''
  
 
If both colonies for your mutant have the correct sequence, choose one to use for the protein purification step. If only one is correct, then this is the one you will use next time.  If neither of your plasmids carry the appropriate mutation, talk to the teaching faculty.
 
If both colonies for your mutant have the correct sequence, choose one to use for the protein purification step. If only one is correct, then this is the one you will use next time.  If neither of your plasmids carry the appropriate mutation, talk to the teaching faculty.

Revision as of 17:36, 29 September 2016

20.109(F16): Laboratory Fundamentals of Biological Engineering

Engelward PNAS 2006.png

Schedule Fall 2016        Announcements        Assignments        Homework        Communication
       1. Measuring Genomic Instability        2. Manipulating Metabolism        3. Engineering Biomaterials              

Introduction

dual plasmid system...

aTc induction...

Protocols

Part 1: Communication Lab workshop

Our communication instructors, Dr. Sean Clarke and Dr. Diana Chien, will join us today for a workshop on organizing and structuring your Research article.

Part 2: Examine psgRNA sequencing results

Your goal today is to analyze the sequencing data for you two potential mutant IPC samples - two independent colonies from your X#Z mutant - and then decide which colony to proceed with for the X#Z mutant.

  1. Use the pRSET-IPC ApE file to mark and/or note down the expected location of your mutation before proceeding.
    • You can simply compare to your annotation of the IPC alone ApE file that you prepared on Day 1 of the module.
    • You may also find it helpful to generate another ApE file with only the CaM portion of IPC and use this when you assess the Genewiz sequencing results.
  2. Your sequencing data from Genewiz is available at this link.
    • Choose the "Login" link and then use "nllyell@mit.edu" and "be20109" to access your results.
    • At the bottom right should be a link to download your sequencing results.
      • TR section: click on the Tracking Number 10-324382914 (Order Date 02-18-2016) and Tracking Number 10-324581564 (Order Date 02/21/2016)
      • WF section: click on the Tracking Number 10-324426168 (Order Date 02-19-2016) and Tracking Number 10-324584038 (Order Date 02/21/2016)
  3. The quickest way to start working with your data is to follow the "View" link under the Seq File heading. For ambiguous data, you may want to look directly at the Trace File as well.

You can align your sequencing data with a known sequence, in this case the CaM portion of inverse pericam, and the differences will be quickly identified. There are several web-based programs for aligning sequences and still more programs that can be purchased. The steps for using APE and the NCBI-hosted tool are below. Please feel free to use either program...or any program with which you are familiar.

Align with Benchling

If both colonies for your mutant have the correct sequence, choose one to use for the protein purification step. If only one is correct, then this is the one you will use next time. If neither of your plasmids carry the appropriate mutation, talk to the teaching faculty.

Align with "bl2seq" from NCBI

  1. The "nucleotide BLAST" alignment program can be accessed through the NCBI BLAST page or directly from this link. The default settings should be fine.
  2. Paste the sequence text from your sequencing run into the "Query" box. This will now be the "query." If there were ambiguous areas of your sequencing results, these will be listed as "N" rather than "A" "T" "G" or "C" and it's fine to include Ns in the query.
    • The start and end of your sequencing may have several Ns. In this case it is best to omit these Ns by pasting only the 'good' sequence that is flanked by the ambiguous sequence.
  3. Paste the pRSET-IPC or CaM sequence into the "Subject" box.
  4. Click on the BLAST button. Matches will be shown by vertical lines between the aligned sequences. You should see a long stream of matches, followed by lots of errors in the last ~200 bp of the sequence.
    • Ignore the error-ridden part of the data, as it may not accurately reflect your mutant plasmid. In this stream of matches, the 1 missing line indicating your mutant codon should stand out. If it doesn't, use the numbering or Find tool to locate the appropriate codon.
  5. Carefully examine the sequence to see if your mutation was incorporated.
  6. You should save a screenshot of each alignment and attach them to your notebook.
  7. Follow the above steps to examine all of your sequencing results. Remember: you used a forward and a reverse primer to interrogate both potentially mutated plasmids.

If both colonies for your mutant have the correct sequence, choose one to use for the protein purification step. If only one is correct, then this is the one you will use next time. If neither of your plasmids carry the appropriate mutation, talk to the teaching faculty.

Part 3: Prepare media for mixed-acid fermentation inoculations